Changing stroke rehab and research worldwide now.Time is Brain! trillions and trillions of neurons that DIE each day because there are NO effective hyperacute therapies besides tPA(only 12% effective). I have 523 posts on hyperacute therapy, enough for researchers to spend decades proving them out. These are my personal ideas and blog on stroke rehabilitation and stroke research. Do not attempt any of these without checking with your medical provider. Unless you join me in agitating, when you need these therapies they won't be there.

What this blog is for:

My blog is not to help survivors recover, it is to have the 10 million yearly stroke survivors light fires underneath their doctors, stroke hospitals and stroke researchers to get stroke solved. 100% recovery. The stroke medical world is completely failing at that goal, they don't even have it as a goal. Shortly after getting out of the hospital and getting NO information on the process or protocols of stroke rehabilitation and recovery I started searching on the internet and found that no other survivor received useful information. This is an attempt to cover all stroke rehabilitation information that should be readily available to survivors so they can talk with informed knowledge to their medical staff. It lays out what needs to be done to get stroke survivors closer to 100% recovery. It's quite disgusting that this information is not available from every stroke association and doctors group.

Showing posts with label hand exoskeleton. Show all posts
Showing posts with label hand exoskeleton. Show all posts

Saturday, July 11, 2026

Exoskeleton Reads Faint Muscle Signals to Overcome Hand Paralysis

 Won't work for me dead motor cortex doesn't send any signals at all.

Exoskeleton Reads Faint Muscle Signals to Overcome Hand Paralysis

Summary: Researchers created an intelligent, low-cost pneumatic glove that successfully restores grasping capabilities to paralyzed hands. By combining inexpensive fabric and smart air cushions with advanced machine learning, the system intercepts weak electromyogram (EMG) signals straight from the forearm.

This allows the glove to read a user’s biological intent with up to 97% reliability, inflating targeted chambers to close fingers safely around glasses, forks, and everyday objects.

Key Facts

  • The 13-Tube Pneumatic Matrix: The soft-hand exoskeleton is constructed using basic, low-cost fabric embedded with specialized air cushions across its outer surface. These cushions are fed by 13 independent micro-tubes, allowing the glove to bend or straighten individual fingers and smoothly rotate the wrist.
  • Deep Intent Prediction: Forearm sensors capture faint electrical muscle impulses (EMG data). The team’s machine learning algorithms process these signals, inferring the user’s intended grasping gesture with an incredible 97% accuracy rate before the hand even attempts to move.
  • The Anti-Drop Safety Shield: To prevent the heartbreak of dropping an item mid-reach, researcher Nicolas Berberich integrated supplementary motion sensors. These sensors detect active transport movements as the arm swings, keeping the exoskeleton’s pneumatic grip firmly locked until the object is safely set down.
  • The ALS Patient Milestone: The system was co-developed and validated in close collaboration with an ALS patient who had lost almost all hand movement, retaining control over only his first thumb joint. By targeting the flexor pollicis longus muscle in the forearm, the system successfully amplified his remaining muscle pulses.
  • A Fork in Four Years: Using the TUM glove, the ALS patient was able to pick up and hold a fork for the first time in four years, manipulate small blocks, and successfully feed himself. Remarkably, just five minutes of training using a specialized thumb-controlled video game was enough to dramatically optimize his operational control.
  • Affordable Democratic Design: Unlike elite, six-figure lab exoskeletons, Dr. John Nassour hand-sewed the fabric glove using highly affordable materials. This low-cost, high-yield engineering design guarantees that the high-tech solution can remain financially accessible to low-income families and everyday stroke survivors.
  • Broad Clinical Horizons: Following the success of the ALS pilot, Professor Gordon Cheng and neurologist Tobias Wächter are expanding the soft glove concept to assist stroke survivors, motorcycle accident victims with peripheral nerve damage, and individuals living with flaccid paralysis or polyneuropathy.

Source: TUM

The Technical University of Munich (TUM) has developed a soft, pneumatic glove that restores the ability of people with paralyzed hands to grasp objects.

Tuesday, December 9, 2025

The Berlin bimanual test for stroke survivors (BeBiT-S): evaluating exoskeleton-assisted bimanual motor function after stroke

 With NO rehab protocols to fix problems after this 'evaluation'; COMPLETELY FUCKING USELESS! Does no one in stroke know how to think?

The Berlin bimanual test for stroke survivors (BeBiT-S): evaluating exoskeleton-assisted bimanual motor function after stroke

    We are providing an unedited version of this manuscript to give early access to its findings. Before final publication, the manuscript will undergo further editing. Please note there may be errors present which affect the content, and all legal disclaimers apply.

    Abstract

    Background

    Brain/neural hand exoskeletons (B/NHEs) can restore motor function after severe stroke, enabling bimanual tasks critical for various activities of daily living. Yet, reliable clinical tests for assessing bimanual function compatible with B/NHEs are lacking. Here, we introduce the Berlin Bimanual Test for Stroke (BeBiT-S), a 10-task assessment focused on everyday bimanual activities, and evaluate its psychometric properties as well as compatibility with assistive technologies such as B/NHEs.

    Methods

    BeBiT-S tasks were selected based on their relevance to daily activities, representation of various grasp types, and compatibility with current (neuro-)prosthetic devices. A scoring system was developed to assess key aspects of bimanual function—including reaching, grasping, stabilizing, manipulating, and lifting—based on video recordings of task performance. The BeBiT-S was administered without support of assistive technology (unassisted condition) to 24 stroke survivors (mean age = 56.5 years; 9 female) with upper-limb hemiparesis. We evaluated interrater reliability through the intraclass correlation coefficient (ICC) and construct validity through correlations with the Chedoke Arm and Hand Activity Inventory (CAHAI), and Stroke Impact Scale (SIS). A subgroup of 15 stroke survivors (mean age 50.3 years, 5 female) completed a second session supported by a B/NHE (B/NHE-assisted condition) to assess the BeBiT-S’ sensitivity to change related to B/NHE-application.

    Results

    The BeBiT-S demonstrated high interrater reliability in both the unassisted (ICC = 0.985, P < .001) and B/NHE-assisted (ICC = 0.862, P < .001) conditions. Unassisted BeBiT-S scores correlated with the CAHAI-8 (r(22) = 0.95, P < .001) and the SIS subscales “strength” (r(20) = 0.53, P = .012) and “hand function” (r(20) = 0.50, P = .018), indicating construct validity. BeBiT-S scores improved significantly with B/NHE assistance (Mdn = 60, P < .05), compared to when no assistance was provided (Mdn = 38, P < .05), demonstrating the test’s sensitivity to change following the application of a B/NHE.

    Conclusions

    The findings support that the BeBiT-S is a reliable and valid tool for evaluating bimanual task performance in stroke survivors and is compatible with the use of assistive technology such as B/NHEs.

    Trial registration NCT04440709, submitted June 18th, 2020.

    Tuesday, March 21, 2023

    An exoskeleton rehabilitation system to train hand function after stroke

    What is your doctor prescribing for your hand recovery? ANYTHING AT ALL? NO? Then you don't have a functioning stroke doctor!  My occupational therapist told me at six weeks that research proved that if you don't have function of the hand at six weeks, it probably won't come back.  What she should have said is: 'I've contacted researchers and they are working on solutions.' But she didn't and 17 years later my left hand is still non-functional and I see nothing that will change that because we have NO strategy to solve stroke. All we have are fucking failures of stroke associations  doing NOTHING FOR STROKE SURVIVORS!

     An exoskeleton rehabilitation system to train hand function after stroke

    Hengyu Li
    Proceedings Volume 12593, Second Guangdong-Hong Kong-Macao Greater Bay Area Artificial Intelligence and Big Data Forum (AIBDF 2022); 1259316 (2023) https://doi.org/10.1117/12.2672155
    Event: 2nd Guangdong-Hong Kong-Macao Greater Bay Area Artificial Intelligence and Big Data Forum (AIBDF 2022), 2022, Guangzhou, China

    Abstract

    Stroke is a leading cause of disability in adults. Notably, about 75% of stroke survivors have upper limb damage, which greatly reduces the quality of life of the patient after recovery. The current routine rehabilitation recommendation is repetitive functional training (exercise-based training) to promote nervous system recovery, and then realize exercise rehabilitation. The cost, efficiency and success rate of traditional treatment methods are unstable due to various factors such as the professional level of therapists, the time required and the workload of therapists. In the case, rehabilitation robot-assisted therapy brings a new direction for the rehabilitation of stroke hemiplegia. In this paper, a new type of hand rehabilitation robot is designed based on the physiological structure of fingers, which is used to assist stroke patients in different stages of finger movement rehabilitation training. It can help the patient to practice grasp adduction and abduction repeatedly, reducing the burden on the patient. Secondly, in this paper, the degrees of freedom and movement of each finger joint are analyzed and calculated. Through modelling and finite element analysis based on Solid works to simulate the stress changes of exoskeleton in different rehabilitation stages, a model suitable for different stages of rehabilitation training is put forward.
    © (2023) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.

    Wednesday, May 11, 2022

    Exoskeleton device helps stroke victims regain hand function

     Has your stroke hospital at least tested out these others? NO? Then you don't have a functioning stroke hospital.

    Exoskeleton device helps stroke victims regain hand function

    Working closely with users and therapists, EPFL spin-off Emovo Care has developed a light and easy-to-attach hand exoskeleton for people unable to grasp objects following a stroke or accident. The device has been successfully tested(I'm sure your definition of success is still failure in survivors eyes.) in several hospitals and rehabilitation centers. Full article: https://actu.epfl.ch/news/exoskelton-... Article en français: https://actu.epfl.ch/news/un-exosquel... Emovo Care : https://emovocare.com/ EPFL: https://www.epfl.ch/  
     
    Video at link.

    Monday, February 28, 2022

    Design and experimental testing of a force-augmenting exoskeleton for the human hand

     You'll have to ask your doctor what they are doing to get this tested for stroke patients. Not doing anything should be grounds for firing.

    Design and experimental testing of a force-augmenting exoskeleton for the human hand

    Abstract

    Background

    Many older Americans suffer from long-term upper limb dysfunction, decreased grip strength, and/or a reduced ability to hold objects due to injuries and a variety of age-related illnesses. The objective of this study was to design and build a five-fingered powered assistive exoskeleton for the human hand, and to validate its ability to augment the gripping and pinching efforts of the wearer and assist in performing ADLs.

    Methods

    The exoskeleton device was designed using CAD software and 3-D printed in ABS. Each finger’s movement efforts were individually monitored by a force sensing resistor at each fingertip, and proportionally augmented via the microcontroller-based control scheme, linear actuators, and rigid exoskeleton structure. The force production of the device and the force augmenting capability were assessed on ten healthy individuals with one 5-digit grasping test, three pinching tests, and two functional tests.

    Results

    Use of the device significantly decreased the forearm muscle activity necessary to maintain a grasping effort (67%, p < 0.001), the larger of two pinching efforts (30%, p < 0.05), and the palmer pinching effort (67%, p < 0.001); however, no benefit by wearing the device was identified while maintaining a minimal pinching effort or attempting one of the functional tests.

    Conclusion

    The exoskeleton device allowed subjects to maintain independent control of each digit, and while wearing the exoskeleton, in both the unpowered and powered states, subjects were able to grasp, hold, and move objects such as a water bottle, bag, smartphone, or dry-erase marker.

    Introduction

    In general, grip strength has been seen to gradually decline between 60 to 75 years of age- this decline more drastically noted among men [1]. Additionally, approximately 795,000 Americans suffer from a stroke, the leading cause of serious long-term disability, per year, reducing mobility, including upper limb dysfunction, in over half of stroke victims age 65 and older [2]. Upper limb dysfunction, including decreased grip strength and/or diminished ability to hold objects is also prevalent in populations with carpal tunnel syndrome [3].

    Robotic exoskeleton devices can be primarily designed to augment user strength in order to assist with activities of daily living (ADLs), or as rehabilitative devices that are used under the guidance of a physical therapist to help patients regain greater functionality of damaged joints and/or muscles [4]. Assistive exoskeletons for the hand can be grouped according to how the augmenting forces enhance the concentric movement of the digits. Devices have been designed to apply the augmenting forces to the dorsal aspect of the fingers via mechanical linkages [5,6,7,8] or fabric-based pneumatic bladders [9]. A ventral approach has also been used, where pseudo-tendons applied tension that is transmitted to the digits through soft [10] or hard exoskeleton structures [11]. Heo, et al. [12] and Bos, et al. [13] have both published comprehensive listings and reviews of exoskeleton devices for the hand.

    Regardless of the technique used to apply the augmenting force, for an assistive device to function, finger movement or another indication of the user’s intent to move must be sensed and transformed into a signal that controls the application of the assistive forces. Ideally, there needs to be a consistent coordination between the device and the user that results in a coupling of the human hand and the augmenting system, allowing the robotic device to consistently provide assistance as needed through the detection and amplification of the user’s effort. Some grip-assistive devices, however, have pre-programed algorithms with which users do not initiate by intent to move. These types of devices, such as the HERO Grip Glove [14] move the user’s hand through gripping and/or pinching patterns that allow for a set force production, which is then augmented by a user’s own strength. Devices by Yap et al. and Polygerinos et al. operate in a similar fashion, where the user shows intent to move, and the device then moves through a pre-determined motion without any subsequent input from a user [15, 16]. Such devices can both be used for hand motion training with the guidance of a physical therapist, as well as assist in ADLs.

    Hand exoskeleton designs vary in overall weight, complexity, and cost. In attempts to provide the full range of motion of the human hand to the user, most of these devices have become both bulky and complex, and due to this are restricted to a single functional activity- either hand-opening or pinching. These exoskeleton devices often use a single motor or driving feature to assist multiple fingers [14], such as with Yoo et al.’s design which used one motor to drive three fingers [17] and Gasser et al.’s design which uses two motors to control four fingers [18]. Alternatively, some devices actively assist fewer than all five fingers [19], for example, Pu et al.’s, Nycz et al.’s, and Gasser et al.’s designs exclude the thumb [6, 18, 20]. Devices that allow for more degrees of freedom and independently assist all five digits become exceedingly cost prohibitive as more joints, motors, and custom electrical components become necessary [5, 21]. These additional motors and therefore batteries will also make the device heavier and potentially tethered to a power source dependent on the current draw [9, 22].

    A previous design from our laboratory used machined aluminum segments to construct exoskeleton digits with a desktop computer-based control system tethered to the device [23, 24]. In order to reduce both the manufacturing cost and time of these previous prototypes as well as the weight, the most recent exoskeletons were designed to be constructed with 3-D printed thermoplastics. Furthermore, a minicomputer-based control system replaced the desktop computer and associated data acquisition hardware, which provided a further reduction in cost, weight, and complexity, and also allowed for greater freedom of movement [11, 25]. Even though exoskeletons with 1 or 2 fingers are simpler to implement, most ADLs require at least 3 fingers to be assisted by an exoskeleton [26]. Exoskeletons with 3 or 4 fingers could assist with most ADLs, the realism for the user would decrease as the number of fingers decrease [26]. Additionally, having fewer fingers limits the grasping positions the user can make with their hand, as well as limit the objects the user can lift. For example, a 4 or 3-fingered exoskeleton could assist a user in picking up objects of uniform shapes (e.g., cup, reusable water bottle) but not objects that are oddly shapes or have varying thicknesses (e.g., cell phone, wine glass). Increasing the number of independently controlled exoskeleton digits would allow for the control to lift objects such as this and increase the mobility to the point where it feels natural to the user. For training and rehabilitation devices specifically, being able to independently control each finger is imperative for re-developing muscle and flexibility in every finger. All these reasons listed are why most modern powered exoskeletons for the human hand use a five-fingered design despite the added complexity and weight [15, 16, 22, 27,28,29], and why we have decided to move from a three-fingered design [11, 25, 30] to a five-fingered design [31].

    The main objective of this study was to design and produce a wearable powered exoskeleton for the human hand to improve structural stability of the fingers while also augmenting pinching and grasping efforts, and to validate that the device augments both the user’s pinching and grasping efforts and ability to perform ADLs by evaluating healthy human subjects. The exoskeleton device should be user friendly, allow for individual finger movement, and be cost optimized. This device aims to not compromise cost and weight for individual, independent movement of all five fingers. To be user friendly, the device must be able to incorporate a range of sizes that users may experience on a daily basis, as well as have a minimal user interface, and be easily donned and doffed. Additionally, the device must be portable and easily carried, and the batteries should last multiple hours. For cost optimization, electronic components must be commercially available, and the device should be modular such that broken parts are able to be replaced as necessary. Additionally, the modularity of the design must be such that different sized pieces are able be added and removed for users of differing size in the future. The exoskeleton structure was designed using CAD (computer aided design) software to enclose all five fingers of the right hand and was 3-D printed in ABS plastic. Each finger’s movement efforts were individually monitored and proportionally augmented via the microcontroller-based control scheme, linear actuators, and rigid exoskeleton structure.

    More at link.

     

    Wednesday, December 8, 2021

    A Modular Soft Robotic Exoskeleton for Active Hand Rehabilitation after Stroke

     With no picture it is impossible to tell whether spastic fingers could ever get this glove on.

    A Modular Soft Robotic Exoskeleton for Active Hand Rehabilitation after Stroke

    Publisher: IEEE

    Abstract:
    This paper presents the design and components of a modular soft exoskeleton for an active hand rehabilitation in people who has suffered a stroke. Most of the exoskeletons designs in which soft technologies are incorporated do not allow movement of the thumb. Our design allows their user to flex and stretch the index finger, the middle finger and the thumb repeatedly with the possibility to train their memory movement by picking and releasing. This was achieved through a soft exoskeleton-like glove design fabricated with a 3D printer with flexible materials. The overall weight of this Soft Exoskeleton-like glove 155 g, not including the battery of 6V, the electronic components and the microcontroller which are placed in the forearm and have total weight of 159 g. Our device is able to provide the forces of 3,9N in cylindric grasp position and 1,6N in precision grasp. These movements are possible because the thumb can move according to the grasping. This could allow future users to train and rehabilitate outside of a specialized center for more frequent training by doing repetitive exercise.
    Date of Conference: 27-29 Oct. 2021
    Date Added to IEEE Xplore: 30 November 2021
    ISBN Information:
    Publisher: IEEE
    Conference Location: Lima, Peru
     

    Saturday, November 20, 2021

    Robotics for rehabilitation of hand movement in stroke survivors

     Still don't know what end-effector is or how to explain to my therapist if I may want one.

    Robotics for rehabilitation of hand movement in stroke survivors

    First Published April 25, 2019 Research Article 

    This article aims to give an overall review of research status in hand rehabilitation robotic technology, evaluating a number of devices. The main scope is to explore the current state of art to help and support designers and clinicians make better choices among varied devices and components. The review also focuses on both mechanical design, usability and training paradigms since these parts are interconnected for an effective hand recovery. In order to study the rehabilitation robotic technology status, the devices have been divided in two categories: end-effector robots and exoskeleton devices. The end-effector robots are more flexible than exoskeleton devices in fitting the different size of hands, reducing the setup time and increasing the usability for new patients. They suffer from the control of distal joints and haptic aspects of object manipulation. In this way, exoskeleton devices may represent a new opportunity. Nevertheless their design is complex and a deep investigation of hand biomechanics and physical human–robot interaction is required. The main hand exoskeletons have been developed in the last decade and the results are promising demonstrated by the growth of the commercialized devices. Finally, a discussion on the complexity to define which design is better and more effective than the other one is summarized for future investigations.

    Over the past years, rehabilitation engineering has played a crucial role in improving the hand and finger function after stroke. The applications of robotics and mechatronic devices have rapidly expanded from the industrial environment to human assistance in rehabilitation and functional improvements. Rehabilitation engineering has increased the quality lives of individuals with disabilities, offering dedicated training that performs better than conventional methods.

    In this way, there are many challenges and opportunities to integrate engineering concepts into hand rehabilitation, and increasing population wellbeing and wealth as well as reducing healthcare costs. This motivates researchers to study, design, and develop novel rehabilitative and assistive technologies and devices to help people to motor functions. Specifically, the current challenge is to transfer the research results and new knowledge to stakeholders creating a general awareness of the importance of rehabilitation engineering.

    This review aims to present and discuss the main robotic technologies for hand recovery rehabilitation in stroke survivors, evaluating and comparing previous and current works and researches. This study explores the current state of art to help and support designers and clinicians make better choices among varied devices and components. The review also focuses on both mechanical design (e.g. concept), usability (e.g. setup, lightness, portability) and training paradigms (e.g. hand, hand/wrist or entire arm) since these parts are interconnected for an effective hand recovery. An overview of the main advantages and drawbacks in applying robotics to hand motor impairments is provided in order to give a general view of the relationship between hand rehabilitation devices, rehabilitation theories and results. The challenge is to restore the hand movements such as opening, closing, grasping and releasing movements. Second, a discussion on the application and new challenges of rehabilitation robotic devices is summarized for future investigations. In particular, the main challenges are to develop safe devices with less complex designs, increasing potential for portability and efficacy. In fact, future development for patient treatment should include the device portability to increase the potential applications. The preliminary results have highlighted the robot-assisted therapy currently works hand in hand rather than a replacement of traditional therapy. Therapies and rehabilitation strategies should be not only more effective but also more cost-efficient.

    Stroke is one of the leading causes of long-term disability, affecting approximately 14% of world’s population.1,2 33% of survivors reports very limited or no functional use of the upper limb.3 Rehabilitation activities based on repeated exercises have been identified suitable in recovering some degree of motion, in particular, a simple flexion and extension of fingers has demonstrated improvements in hand functionality.4,5 In this way, medical devices and robot-assisted strategies may provide a number of advantages guaranteeing the range of motion (ROM) and avoiding inappropriate movements. Nevertheless, only a limited part of the proposed devices by the literature has been clinically tested, highlighting as the design complexity and development costs may negatively impact the system implementation. The previous and current robots and devices are often too complex to be used by patients limiting any testing on the real users.

    Note that the hand functional improvement may be the result of a set of compensatory strategies based on an initial support assisted by the physiotherapist. Usually, these approaches may be suggested during the first months after stroke, when the impairment reduction may be preferred to extensive functional training. In this phase of impairment, the patients show a loss of control and a decreased tactile sensation and proprioception, reducing the physical independence and social integration. The patient’s motivation associated with verbal encouragement may significantly impact the therapy efficacy.

    Over the last decades, a set of studies has evaluated the influence of the robot-assisted therapies on arm motor improvement and impairment reduction using randomized clinical controlled trials.612 The obtained results have not shown a complete consensus; nevertheless, the therapy assisted by robotics seems to obtain results beyond what is done by conventional methods.1317 In particular, researchers have been slow to investigate the hand function due to the complexity of this limb.11,12,1820

    In any case, a number of studies observed that the rehabilitation training can improve the hand motor in terms of pull, push, and grip strengths, confirming that robotic training is at least as effective as conventional training.13,2124 A significant part of the obtained outcomes have been also proved by Fugl-Meyer Assessment (FMA) and Functional Independence Measure (FIM) tests, performed after the robot treatment.2527

    Despite these promising results, the literature review shows also researches that did not observed significant difference between conventional and robotic training groups, highlighting as the conventional therapies are more effective in decreasing levels of impairment and disability.2,8,28,29 Mazzoleni et al.29 and Colombo et al.30 have underlined that there are other significant factors that may impact the efficacy of the training outcome, such as recovery stage, intensity, or duration of the rehabilitation therapy. This point needs to be considered to evaluate and compare different therapy treatments. In the light of these considerations, there are not evident conclusions that sustain the robot-therapy efficacy, suggesting further investigations.31,32

     More at link.

    Sunday, August 15, 2021

    An EMG-controlled robotic hand exoskeleton for bilateral rehabilitation

     6 years for your doctor to get this installed in their hospital. How well did they do?

    An EMG-controlled robotic hand exoskeleton for bilateral rehabilitation


    Abstract:
    This paper presents a novel electromyography (EMG)-driven hand exoskeleton for bilateral rehabilitation of grasping in stroke. The developed hand exoskeleton was designed with two distinctive features: (a) kinematics with intrinsic adaptability to patient's hand size, and (b) free-palm and free-fingertip design, preserving the residual sensory perceptual capability of touch during assistance in grasping of real objects. In the envisaged bilateral training strategy, the patient's non paretic hand acted as guidance for the paretic hand in grasping tasks. Grasping force exerted by the non paretic hand was estimated in real-time from EMG signals, and then replicated as robotic assistance for the paretic hand by means of the hand-exoskeleton. Estimation of the grasping force through EMG allowed to perform rehabilitation exercises with any, non sensorized, graspable objects. This paper presents the system design, development, and experimental evaluation. Experiments were performed within a group of six healthy subjects and two chronic stroke patients, executing robotic-assisted grasping tasks. Results related to performance in estimation and modulation of the robotic assistance, and to the outcomes of the pilot rehabilitation sessions with stroke patients, positively support validity of the proposed approach for application in stroke rehabilitation.
    Published in: IEEE Transactions on Haptics ( Volume: 8, Issue: 2, April-June 1 2015)