Our researchers should be jumping for joy about getting drugs past the blood brain barrier for those possibilities that can stop the neuronal cascade of death. But is it the sonication or the gas in the microbubbles that is the cause of entry? Can't we even figure out cause and effect? Earlier research used xenon gas which has a proven neuroprotective effect.
I await results in 20 years unless we take over.
Propping Open the Door to the Blood Brain Barrier
The treatment of central nervous system (CNS) diseases can
be particularly challenging because many of the therapeutic agents such
as recombinant proteins and gene medicines are not easily transported
across the blood-brain barrier (BBB). Focused ultrasound can be used to
"open the door" of the blood brain barrier.
However, finding a way to "prop the door open" to allow therapeutics
to reach diseased tissue without damaging normal brain tissue is the
focus of a new study by a team of researchers at the Institute of
Biomedical Engineering at National Taiwan University presenting at the
57th Annual Meeting of the Biophysical Society (BPS), held Feb. 2-6,
2013, in Philadelphia, Pa.
The group is investigating the feasibility of using heparin, a common
anticoagulant, to enhance the delivery of therapeutic macromolecules
using ultrasound into the brain. Heparin could be employed to increase
treatment efficacy in patients with different types of CNS diseases
under the guidance of medical imaging system providing new hope in these
challenging cases. Initial results show that heparin does have the
potential to optimize therapeutic delivery with ultrasound, acting as a
"doorstop," allowing drugs to better permeate the BBB and enhancing
treatment success.
"A higher acoustic pressure and longer sonication, and/or a higher
dose of microbubbles may increase the delivery of drugs or tracers into
the sonicated brain tissue," explains Kuo-Wei Lu, a member of the
research team, "but side-effects, such as microhemorrhage, can also
increase dramatically. The results of this study indicate that heparin
may offer a safer way can to enhance the delivery of therapeutics to
patients with CNS diseases."
With these encouraging results, the next step for the team is to
develop a focused ultrasound system with Magnetic Resonance Imaging
(MRI) guidance to establish suitable parameters needed for patient
clinical trials. "Focused ultrasound sonication is a noninvasive
technology capable of localized and transient BBB opening for the
delivery of CNS therapeutics," Lu states. "We hope by developing
suitable parameters and using chemical enhancers like heparin, this can
be a valuable tool in the treatment of patients with CNS diseases,
opening the door to better patient outcomes."